Translate In : View in English View in Spanish View in French View in German View in Italian View in Chinese (Simplified) View in Japanese View in Korean View in Arabic View in Portuguese
 
 
 
 
Chargewave Energykem Pvt. Ltd.
 

Support from Chargewave
Support from Chargewave
Activiser FB
Activiser FB
CFBC Boilers
CFBC Boilers
FBC Boilers
FBC Boilers
Manual Fired Boilers
Manual Fired Boilers
Actigain ST
Actigain ST
Stoker / Spreader Stoker Boilers
Stoker / Spreader Stoker Boilers
Actimix for Manual Mixed Fuel Fired Boilers
Actimix for Manual Mixed Fuel Fired Boilers
General Safety Information
General Safety Information
Pulverised Fuel Boilers
Pulverised Fuel Boilers
Actigain for Manual Biomass Fired Boilers
Actigain for Manual Biomass Fired Boilers
Actigain FB
Actigain FB
Actimix FB
Actimix FB
Blast Furnace
Blast Furnace
Downloads
Downloads
Submerged Arc Furnace
Submerged Arc Furnace
Coal Fired Cement Rotary Klins
Coal Fired Cement Rotary Klins
Sponge Iron Kilns
Sponge Iron Kilns
Vertical Shaft Kilns
Vertical Shaft Kilns
Foundry Cupola
Foundry Cupola
Rockwool Cupola
Rockwool Cupola
Downloads
Downloads
Home » Products » Boiler Applications » Actigain ST

Actigain ST



<< Previous   Actigain ST   Next >>

Product Code : ST 06

Product Specification

 






Salient Features of Actigain Technology





Classified Chemical Invention @ IENA Germany 2010 Designed for Performance in High Thermal Efficiency Stoker / Spreader Stoker Fired Boilers
Downloads Registers the best results in the Highest Thermal Efficiency Operating condition Results over & above GCV of the input Biomass Downloads
Project Reports Temperature, Gas, Steam Profiles, remain unchanged. Effect on input Kcal only Boiler Optimization
Boiler Data Sheets Lesser Black Smoke, CO2 emissions Lesser Clinker formation Sales Initiatives
Lower LOI Lower Kcal / MT Steam
Technical Presentation Tests in PTC 4.1, Direct Method Comparison report on Kcal / MT Steam Safety Information
Steam Cost Reduction between 15 to 24% (Identical Biomass fuel or GCV)

Technical Support for maximizing Boiler Performance through Chargewave Energy-Pro Combustion Projection Software

Results Proof in Storage Yards, Purchases, Balance Sheets within 3 to 6 months
Easy to Implement & Establish








Assured Advantages in Wide Span of Boiler Design
Actigain Chemicals are well established to lower Steam Generation Costs in all types of High / Medium Thermal Efficiency Stoker / Spreader Stoker Biomass fired Boilers (Thermax / CVL / IBL / Veesons / Santhi / Thermal Systems / Cheema & any other Boiler Manufacturers)




Laces Extra Fire Power & Combustion Power to your fuel
Actigain Chemicals are specially designed Inorganic chemicals for lacing extra Fire Power & Combustion Power to all types of Biomass employed in High Thermal Efficiency operating Manual Fired boilers. Works well with (Wood, Groundnut husk, Rice Husk, Biomass waste, any biomass fuel)




Alters Thermal Energy Generation to create more impact
Actigain targets the floor conditions for proper CO2 reaction & raises the combustion reaction efficiency by 25 to 30% over the mechanically induced condition. Carbon & Oxygen thus vigorously react in the most efficient conditions releasing energy in uniform, highly concentrated, intensive heat cycles with 25% more fire & impacting power




Reaction Conditions Comparison-Table
Parameter Mechanically Induced Condition Chemically Induced Condition
Reaction Efficiency of CO2 65% to 75% 95% to 99%
Thermal Energy & Intensity Scattered & Normal Concentrated & Very High
Heat Energy Cycles Variable band width Single band width
Thermal Power & Impact Normal + 25%
Steam Profile As Operation As Operation (No Change)
Temperature Profile As Operation As Operation (No Change)
Boiler Thermal Efficiency % As Operation As Operation (No Change)
Input Kcal / MT Steam Normal 15 to 20% Less
Steam Generation Cost / MT Normal 15 to 20% Less




Dosage Information
Dosage 1.2 to 1.5Kg / MT fuel through Vibratory feeders




3 Steps to Lowering Steam Cost
Step 1 : Make available Boiler Design & Operation Information (Download Boiler Information Data Sheet)
Step 2 : Nominate Management Representative, Local / Third Party Energy Auditors for data Acquisition & Certification
Step 3 : Conduct PTC 4.1 Direct method & Compare Kcal/MT Steam With & Without Actigain application




(Pre-requisites for PTC 4.1 Direct Method)
Performance / Application under Highest Thermal Efficiency, Boiler Operating Condition
Biomass MT, Moisture%, GCV reports
Working Condition of Water / Steam Flow Meter, Boiler Instrumentation
Permission to Implement & comply suitable turbulence conditions for Actigain working




Results Declaration
Straight Comparison of Steam Generation Cost(Kcal Cost / MT Steam)




 

 

 

 

Other Products in 'Boiler Applications' category
Actimix ST
Actimix ST
Support from Chargewave
Support from Chargewave
Downloads
Downloads
FBC Boilers
FBC Boilers
Activiser FB
Activiser FB
Actigain for Manual Biomass Fired Boilers
Actigain for Manual Biomass Fired Boilers
 
View all products(17)
 
<< Back


 
 
Chargewave Energykem Pvt. Ltd.
No. 15, 2nd Floor, Deepthi Apartments 9-1-7/83-84, SP Road, Secunderabad - 500003, Andhra Pradesh, India
Mr. P. S. Anand Prakash (Director Technical)
Mobile :+919246229300, +917799088822
Mr. V Viswanadha Raja (Manager Marketing)
Mobile :+919246229302, +917799088833
Phone :91-40-27713724
Fax :91-40-27713725
Contact Now
  
 
 
Translate In : View in English View in Spanish View in French View in German View in Italian View in Chinese (Simplified) View in Japanese View in Korean View in Arabic View in Portuguese
Copyright © 2011-12 by CHARGEWAVE ENERGYKEM PVT. LTD. All Rights Reserved.